Boundary perimeter fence is essential for the security and safety of sea port, airport, wharf, various facilities, spaces and sites.
We supply high security perimeter mesh fence systems: Metal galv. mesh fencing panels, entrance / access gates and razor barbed wire. A variety of galvanized finishes as well as a variety of installation methods are provided for perimeter or boundary security fencing applications.
Fencing panels
Galvanised steel wire mesh, plastic coated, 3.55diameter, 50mm opening, with galvanized posts 76mm diameter, at 3m intervals
Hole type: Diamond
Fence frame support:
Post: 76.1x3.2 CHS Galvanised Steel
Brace rail 48.3 x 3.2 CHS every 30 m
Strut 76.1 Diameter x 3.2 CHS Galvanised steel
Typical Boundary Perimeter Security Gate
Double hang entrance gate 6000mm x 2400mm complete with accessories
Pedestrian access gate 1000mmx2400mm complete with accessories
Double hang internal entrance gate 4000mmx2400mm complete with accessories
Framed fencing gate:
48.3x3.2 CHS galvanised for gate internal framing
60.3x3.2CHS galvanised for gate main frame
Hinges 219.1x6.3 CHS galvanised gate post
Plate: Mild steel 350x350x8mm
Tower bolt: 18mm diameter
Strut: 114.3 x 5 CHS strut
Plate: Mild steel 250x250x8mm
Concrete surrouned 600x300x400 deep
Fixing of Mesh Panels and Barbed Wire
Extension arms 70x70x6mm thick angles. Inclined outwards and welded to the top of the post prior to galvanising.
BS4102 standard Barbed wire
Straining posts at all ends and corners of the fence, at changes in direction and at intervals not exceeding 60 m on straight length of the fence.
Line wires 3.55 diameter, galvanized steel and strained tightly by means of eye bolt and stretcher bar or winders at each straining post.
Double line wire: First line wire threaded through adjacent rows of meshes
Second line wire strained in front of fencing wire ties at 150 c/c, 1.6 diameter galvanised steel wire
Galvanised mild steel dropoper 25x5mm thick plate
Dropper at center of each bay
8mm thick gusset plate welded to fence post prior to galvanising
6mm CFW fixed to struts using M16 bolts
Installation Notes
Mass concrete to be grade 30/20/S.
End of hollow sections to be capped or sealed.
All concrete faces to coated with two coats of bituminous paint.
All steel sections to be hot dip galvanised BS729 standard. Minimum coating weight 460 gram per square meter.
450x450x500 deep concrete foundation for corner post
Typical Fence Design
Post, rails, strut and foundations details:
Galvanised Steel Wire Mesh Fencing Panels with Anti Climbing Galvanised Steel Barbed Wire
Mesh, line wire, straining wire, strut, post, stirrup wires, barbed wire, arms, concrete base details:
Typical Main Gate
Frame, panels, post, concrete foundation details for 6m main main gate
48.3x3.2 CHS galvanised for gate internal framing
60.3x3.2CHS galvanised for gate main frame
4m Wide Entry Gate
48.3x3.2 CHS galvanised for gate internal framing
60.3x3.2CHS galvanised for gate main frame
Hinges 219.1x6.3 CHS galvanised gate post
Tower bolt: 18mm diameter
1m Wide Pedestrian Access Gate
Typical design:
48.3x3.2 CHS galvanised for gate internal framing
60.3x3.2CHS galvanised for gate main frame
Hinges 219.1x6.3 CHS galvanised gate post
Tower bolt: 18mm diameter
350x350x8mm thick mild steel plate